BCIN · House exam

House lessons

The House exam syllabus, section by section: Division A, Division C, Part 9 and the other Parts of Division B the syllabus names. Each lesson starts with a guess, gives you the map and the reasons, and ends with a 3-question check, book closed.

57 of 66 planned lessons are live. New lessons are added in batches, in syllabus order. Syllabus: Ministry of Municipal Affairs and Housing, House syllabus (last updated January 21, 2026).

Study notes, not an official interpretation. About these notes

Only the Minister’s binding interpretations (Act s.28.1) and the decisions of the chief building official on a real project are authoritative.

Quoted provisions are from the Building Code Act, 1992 (e-Laws consolidation current from June 2, 2026) and the 2024 Building Code, O. Reg. 163/24 (Compendium, January 16, 2025 update). Code amendments made after January 2025 (November 2025, April 2026 and July 2026) are not yet reflected.

Summaries, explanations and examples are ours: confirm against the official text of the Act and the Code before relying on anything.

Division A · Compliance, scope and objectives

How the Code applies, which Part governs a building, defined terms, referenced documents, climatic data, objectives and functional statements.
Div. A 1.1–1.3.2
Application, compliance and the three Divisions
What the Code applies to, the two ways to comply, what each Division does, and when used materials can go back into a building.
Not started Start
Div. A 1.3.3–1.3.4
Which Parts apply: Part 9 scope and existing buildings
When Part 9 governs a building, how firewalls and fire separations affect building size, how the Code treats existing and moved buildings, and which structures count as buildings.
Not started Start
Div. A 1.4–1.5 · Div. B Part 1
Defined terms, referenced documents and climatic data
How to read italic and plain words, which edition of a referenced standard applies, and where climatic values and frost depth come from.
Not started Start
Div. A Parts 2–3
Objectives, functional statements and SA-1
What the objectives and functional statements are, when they apply, and how SA-1 ties them to each acceptable solution.
Not started Start

Division C · Administration

Conditional permits, paperwork on site, occupancy before completion, inspection notices, alternative solutions and rulings.
Div. C 1.1–1.3.2
Conditional permits and paperwork on site
Which applicable laws must be met before a conditional permit, the two zoning exemptions, and what must be posted and kept on site.
Not started Start
Div. C 1.3.3–1.3.6
Early occupancy, inspection notices and as-constructed plans
When a new house needs an occupancy permit, when an unfinished residential building can be occupied, which inspection notices are required, and when as-constructed plans can be asked for.
Not started Start
Div. C 2.1 · 2.4
Alternative solutions, rulings and interpretations
What an alternative solution proposal must document, how it may be tested, and the Code’s rules for Minister’s rulings and interpretations.
Not started Start

Part 9 · Housing and small buildings

Division B, Part 9 as the House syllabus lists it, Section 9.1 to Section 9.41.
Div. B 9.1 · 3.1.20.1
Part 9 application, site hazards and factory-built buildings
Where Part 9 sends you for its scope, overhead power lines, radon areas, flood plains, and when a factory-built house is deemed to comply.
Not started Start
Div. B 9.3
Concrete, lumber and sheet metal
Concrete strengths and mixes, cold-weather pouring, lumber grades and moisture, undersized lumber, termite and decay protection, and galvanized steel.
Not started Start
Div. B 9.4
Structural design routes, snow loads, deflection and soil
The three ways to design a Part 9 structural member, how snow loads are calculated, deck and attic loads, deflection limits, and allowable bearing pressures.
Not started Start
Div. B 9.5.1–9.5.4
Room areas, ceiling heights and spaces
How rooms are measured, the minimum areas for living, dining, kitchen and bedroom spaces, ceiling heights, bathrooms and hallway widths.
Not started Start
Div. B 9.23.1–9.23.7
Wood framing: limits, fastening, notching, anchorage
When Section 9.23 applies, protecting wood from decay and dampness, connectors for treated wood, nailing, limits on holes and notches, anchoring the frame to the foundation, and sill plates.
Not started Start
Div. B 9.23.4 · 9.23.8–9.23.9
Spans, beams and floor joists
Using the span tables, steel beams, concrete toppings and heavy roofing, beam bearing and built-up beams, joist bearing and hangers, strapping and bridging, openings, wall support and cantilevers.
Not started Start
Div. B 9.23.10–9.23.13
Wall framing: studs, plates, lintels and bracing
Stud sizes and spacing, bracing, stud orientation and continuity, studs at openings and under girders, wall plates and top plate joints, lintels, and bracing walls against wind and earthquake.
Not started Start
Div. B 9.23.14–9.23.17
Roof framing, subfloors and sheathing
Rafters and ceiling joists, openings, ridge support and rafter ties, hip and valley rafters, trusses, subflooring, roof sheathing and wall sheathing.
Not started Start
Div. B 9.24
Sheet steel stud wall framing
Where Section 9.24 applies, stud thickness and runners, steel studs in fire separations, installing runners, expansion clearance in fire-rated walls, framing around openings and fire dampers.
Not started Start
Div. B 9.25
Insulation, air barriers and vapour barriers
Required insulation and its installation, loose-fill limits, the air barrier system and its continuity, vapour barrier materials and placement, and where low-permeance materials may go.
Not started Start
Div. B 9.26.1–9.26.6
Roofing: materials, slope, flashing, eaves, underlay
What roofing must do, material standards, roofing nails and staples, slope limits and back-slope, flashing at walls, valleys, masonry and chimneys, eave protection and underlay.
Not started Start
Div. B 9.26.7–9.26.18
Shingles, shakes, built-up and other roofing
Asphalt shingles on normal and low slopes, wood shingles and shakes, built-up roofs, selvage roofing, sheet metal, panels, membranes, concrete tiles, roof drains and downspouts.
Not started Start
Div. B 9.27.1–9.27.5
Cladding: rain protection, flashing and attachment
Which path applies to each cladding, first and second planes of protection, clearances, sheathing membranes, face-sealed cladding, flashing, sealants, and attaching cladding with blocking, furring and fasteners.
Not started Start
Div. B 9.27.6–9.27.14
Cladding types: wood, panels, metal, vinyl, EIFS
Lumber siding, wood shingles and shakes, plywood, hardboard, OSB and waferboard, metal, vinyl and polypropylene siding, and exterior insulation finish systems.
Not started Start
Div. B 9.28
Stucco
Sheathing and lath under stucco, clearance above ground, flashing, materials, fasteners, lath and its fastening, mixes, cold weather, and the three coats.
Not started Start
Div. B 9.29
Interior wall and ceiling finishes
Waterproof finishes at tubs and showers, furring, plaster, gypsum board and its fastening, plywood, hardboard, fibreboard, particleboard and OSB finishes, and ceramic and plastic tile.
Not started Start
Div. B 9.30
Flooring
Required finished flooring, water-resistant floors, sleepers, panel-type underlay and its fastening, wood strip flooring, parquet, resilient flooring on slabs, and ceramic tile.
Not started Start
Div. B 9.31 · 9.33.6.14A · 9.34
Plumbing, dryer exhaust and electrical facilities
Required water supply, fixtures, laundry, floor drains and service water heaters in dwelling units; independent dryer exhaust ducts; required lighting outlets at entrances, rooms, stairs, basements and garages.
Not started Start
Div. B 9.35
Garages and carports
When a carport counts as a garage, garage floor drainage, foundations and the small detached garage exemption, soil movement and frost, carport piers, finishes, columns and anchorage.
Not started Start
Div. B 9.37–9.39
Cottages, log buildings and park model trailers
What seasonal recreational buildings are exempt from and what they still need, log construction, and park model trailers built to CAN/CSA-Z241.
Not started Start
Div. B 9.40–9.41
Cold room slabs and change of use
Reinforced concrete slabs over basement cold rooms, and the rules for a change of use in an existing Part 9 building: what counts, and how performance level is kept.
Not started Start
Div. B 9.5.5 · 9.6
Doorway sizes, glass and safety glazing
Minimum doorway sizes inside dwelling units, wider bathroom doors on a barrier-free path, and where safety glazing is required.
Not started Start
Div. B 9.7
Windows, doors, skylights and forced entry
Entrance doors, minimum window glass areas, performance and thermal requirements, door and window security, and installation.
Not started Start
Div. B 9.8.1–9.8.4
Stairs: width, headroom, rise, run and treads
Stair widths and headroom, stair configurations, rise and run limits, uniformity tolerances, winders, spiral stairs, nosings and open risers.
Not started Start
Div. B 9.8.5–9.8.6 · 9.8.9–9.8.10
Ramps, landings and stair construction
Ramp width, headroom and slope, where landings are needed and how big they must be, design loads, stringers, treads and cantilevered concrete steps.
Not started Start
Div. B 9.8.7–9.8.8 · SB-7
Handrails and guards
Where handrails are required and how high, graspability and loads, where guards are required, guard heights and loads, openings, climbing and glass.
Not started Start
Div. B 9.9.1–9.9.8
Means of egress: exits, doors and travel distance
Occupant load, types of exits, exit widths and heights, fire protection of exits, obstructions, exit doors, access to exits and travel distance.
Not started Start
Div. B 9.9.9–9.9.12
Egress from dwellings, bedroom windows, signs, lighting
How far you can travel up or down inside a unit, when a second means of egress is needed, bedroom egress windows, exit visibility and egress lighting.
Not started Start
Div. B 9.10.1–9.10.4
Fire protection: scope, ratings and building height
What Section 9.10 hands to Part 3, occupancy classification, how ratings are determined, which side of an assembly is exposed, and when mezzanines count as storeys.
Not started Start
Div. B 9.10.5–9.10.8
Membrane openings, construction types and floor ratings
Openings in rated membranes, combustible and heavy timber construction, protecting steel, and the fire-resistance ratings for floors, roofs and supporting walls, including when houses are exempt.
Not started Start
Div. B 9.10.9
Fire separations: continuity, penetrations, suites, garages
How fire separations and smoke-tight barriers stay continuous, what may pass through them, and the ratings between suites, occupancies and garages.
Not started Start
Div. B 9.10.10–9.10.12
Service rooms, firewalls and fire spread at walls
When service rooms and fuel-fired appliances need a separated room, firewalls and party walls, where floors end, skylights, walls meeting at an angle and soffits.
Not started Start
Div. B 9.10.13 · 9.10.16
Closures, garage doors and fire blocks
Closure ratings for openings in fire separations, wood doors, wired glass and glass block, latches and closers, fire dampers, doors from attached garages, and fire blocks in concealed spaces.
Not started Start
Div. B 9.10.14
Spatial separation between buildings
For Part 9 buildings other than houses: exposing building faces, limiting distance, how much unprotected opening is allowed, and how the exposing wall must be built.
Not started Start
Div. B 9.10.15
Spatial separation between houses
For houses and houses with a secondary suite: glazed openings by limiting distance, and when the exposing wall needs a fire-resistance rating and noncombustible cladding.
Not started Start
Div. B 9.10.17
Flame-spread limits and foamed plastics
Surface flame-spread limits for walls, ceilings and doors, stricter limits in exits and public corridors, combustible skylights, protecting foamed plastic insulation, and bathroom finishes.
Not started Start
Div. B 9.10.18–9.10.19
Fire alarm systems and smoke alarms
When a Part 9 building needs a fire alarm system and detectors, and where smoke alarms go in dwelling units and houses with a secondary suite, how they are powered, interconnected and silenced.
Not started Start
Div. B 9.10.20 · 9.10.22
Firefighting access and clearances at cooktops
Access windows and panels for firefighters, access to large basements, fire department access routes, and clearances and protection around cooktops.
Not started Start
Div. B 9.11
Sound transmission between dwelling units
The ASTC and STC routes to sound protection between dwelling units, how ratings are tested or taken from SB-3, and how flanking constructions must be built.
Not started Start
Div. B 9.12
Excavation, foundation depth and backfill
Preparing and protecting the excavation, minimum foundation depths by soil and drainage, exemptions for light buildings and decks, backfill and trenches under footings.
Not started Start
Div. B 9.13 · SB-9
Dampproofing, waterproofing and soil gas control
When foundation walls and floors are dampproofed or waterproofed, which materials and preparation are needed, protection of interior finishes, and soil gas and radon rough-ins.
Not started Start
Div. B 9.14
Foundation drainage and surface drainage
Drainage at the bottom of foundation walls, drainage layers, drain tile and granular drainage, sump pits and dry wells, and grading the site so water runs away.
Not started Start
Div. B 9.15.1–9.15.3
Footings: application, materials, widths and thickness
When Section 9.15 applies, foundation materials and piers, where footings are needed, minimum footing widths and areas with their adjustments, thickness and step footings.
Not started Start
Div. B 9.15.4–9.15.6
Foundation walls: thickness, support and finishing
Foundation wall thickness and reinforcement, when walls count as laterally supported, ICF foundation walls, height above grade, control joints, supporting joists and beams, and finishing.
Not started Start
Div. B 9.16–9.17
Floors-on-ground and columns
Granular fill, drainage and concrete for floors-on-ground, and the sizes, bearing plates and support of steel, wood, masonry and concrete columns.
Not started Start
Div. B 9.18–9.19
Crawl spaces and roof spaces
Heated and unheated crawl spaces, access, ventilation, ground cover and plenums, and attic and roof space venting, clearances and access hatches.
Not started Start
Div. B 9.20.1–9.20.9
Masonry walls: units, mortar, thickness and ties
Where Section 9.20 applies, masonry units and mortar, joints, support and lintels, wall and veneer thickness, chases, bearing of joists and beams, and bonding and tying wythes and veneer.
Not started Start
Div. B 9.20.10–9.20.17
Masonry: lateral support, anchors, flashing, ICF walls
Lateral support and anchorage of masonry walls, corbelling, flashing and weep holes, cold-weather work, reinforcement and corrosion protection, and above-ground flat ICF walls.
Not started Start
Div. B 9.21
Masonry and concrete chimneys and flues
Which chimneys Section 9.21 covers, what a flue may serve, liners, chimney height, stability, caps and cleanouts, and clearances from combustible framing.
Not started Start
Div. B 9.22
Fireplaces
Combustion air, liners and wall thickness, fire chamber depth, hearths, dampers and smoke chambers, factory-built fireplaces, clearances to combustibles, and inserts.
Not started Start

Division B · Other Parts and supplementary standards

The named Articles of Parts 3, 4, 5, 6, 7, 11 and 12, with SB-7, SB-9 and SB-12.
Coming soon
Div. B 3.1Part 3 named Articles: materials, ratings and firewallsComing soon
Div. B 3.2.1–3.2.3Part 3 named Articles: building height, sprinklers and spatial separationComing soon
Div. B 3.2.4–3.8Part 3 named Articles: alarms, standpipes, exits, services and healthComing soon
Div. B 4.1–4.3Part 4: loads, foundations and structural materialsComing soon
Div. B Part 5Part 5: environmental separationComing soon
Div. B 6.2–6.3 · 7.1–7.6Parts 6 and 7: named HVAC and plumbing ArticlesComing soon
Div. B 11.5Part 11: compliance alternatives for renovationComing soon
Div. B 12.1–12.3 · SB-12Part 12: energy efficiency for housesComing soon
Div. B 12.4Part 12: water efficiencyComing soon
Outside HouseStudying for a different exam?Go back to the exam picker. Designer legal/process and General legal/process are live; other BCIN exams are added one at a time. All exams